ProtumLink Core 50cm

Column length50cm
Column diameter75μm, 150μm
Stationary phase1.9μm C18

Product Description

Maximum Resolving Capacity

Core Benefit: Ultra-Deep PTM and Structural Proteomics

The 50 cm column is the most resolving option in the series, intended for the highest-depth analyses, where maximum peak capacity and sensitivity are required.

Chromatographic Excellence (FWHM Resolution)

Chromatographic excellence chart showing FWHM resolution of the 75µm column

Measured at 250 nL/min, the column achieves ~5.7 s FWHM over ~95 min gradients, offering the separation space necessary to distinguish low-abundance and closely eluting peptides. This is particularly impactful for PTM mapping, deep clinical proteomics, and complex structural studies.

Backpressure Flexibility & Workflow Versatility

With an operational range of 100–400 nL/min, the 50 cm column performs reliably over long analytical sequences and requires stable UHPLC pressure capability. It is the preferred option when analytical depth, precision, and confidence take priority over throughput.

Pressure profiles

Pressure profiles chart showing backpressure vs flow rate of the 75µm column

Maximum Load Resolution

Core Benefit: Ultra-Deep PTM Mapping and Structural Studies

The 50 cm (150 µm ID) column is tailored for applications where the greatest level of separation detail is needed, especially for large sample inputs and structurally complex proteomes.

Chromatographic Excellence (FWHM Resolution)

Chromatographic excellence chart showing FWHM resolution of the 150µm column

With 200 ng load at 0.5 µL/min, it achieves an FWHM of ~5.33 s over a 60-minute gradient, providing the highest resolving power in the series and enabling confident identification of low-abundance and closely eluting peptides.

Backpressure Flexibility & Loading Capacity

Optimized for stable operation at 0.5 µL/min, and supporting up to 1 µL/min, the column remains dependable for long analytical sequences despite its length. Its combination of load tolerance, resolution, and operational robustness makes it a strong choice for deep structural proteomics, PTM-focused studies, and translational research requiring maximum confidence.

Pressure profiles

Pressure profiles chart showing backpressure vs flow rate of the 150µm column

Compatibilities

Core columns are bare fused-silica emitter-integrated analytical columns designed to be connected via a liquid junction. With an outer diameter of 363 μm, they are compatible with liquid junctions engineered for standard 360 μm fused-silica tubing. Depending on the instrument setup, metal junctions can provide grounding or high-voltage transfer, while PEEK junctions may be used when an external grounding or voltage supply point is available. Core columns can also be mounted directly in nanospray sources that are designed to accept bare emitter tips. This includes Thermo Scientific Nanospray Flex and Bruker CaptiveSpray sources (with appropriate emitter positioning accessories such as the CaptiveSpray (CSI) emitter adjustment kit), enabling use of the column itself as the electrospray emitter and minimizing post-column volume. Specific adapter configurations may be required depending on the vendor ion source when using bare emitter columns. Users should consult instrument documentation where compatibility with blank-emitter columns is explicitly described.

Compatible Connection Systems

• Thermo Scientific 6041.5290 nanoViper Fingertight Fitting System, 20 μm

Recommended Liquid Junction Options

• IDEX UH-750 VHP MicroTee® • IDEX UH-634 VHP MicroTight®

C18 Bead Specification

Specification Table

PropertySpecification
Silica BrandReproSil-Pur 120 C18-AQ (Dr. Maisch GmbH)
Chromatographic ModeReversed-phase
Particle Size1.9 µm
Pore Size120 Å
Surface Area300 m²/g
Bonding / PhaseC18 (ODS), fully end-capped, aqueous-compatible
Carbon Load15%
pH Stability Range2 – 8
Max Operating Pressure≤ 1200 bar
Max Operating Temperature60 °C*

*Ultra-fast gradients may be operated up to 70 °C.

Why We Use a Trusted C18 Phase

We rely on a well-established C18 material from Dr. Maisch because it has been widely used in LC–MS–based proteomics for nearly two decades and is known for its stable bonding chemistry, consistent material quality, and reproducible performance. This makes it a dependable foundation for achieving high-quality peptide separations across diverse workflows. The 1.9 µm C18 particles provide a balanced combination of peak capacity, mechanical robustness, and retention stability, supporting sharp and predictable peak shapes under the aqueous mobile-phase conditions typical for proteomics.

Application Notes

Ultra robust performance stability of 25 cm × 75 µm Emitter-Integrated Nanoflow Column with 1.9 µm C18 Material over 800 Samples

PDF - 1.5 MB

Download

High-Sensitivity and Reproducible DIA Performance of a 15 cm × 75 µm Emitter-Integrated Nanoflow Column on the Orbitrap Astral System

PDF - 1.1 MB

Download

Packages

Single400.00€
5-pack1,600.00€
-20% per column
10-pack2,400.00€
-40% per column

Column ID (Diameter)

Sub-total-€
ProtumLink

Our Products

  • ProtumLink Core
  • ProtumLink Union
  • ProtumLink Connect
  • ProtumLink Extend
  • Featured Techniques

About Us

  • About Us
  • Support

Our Stores

  • Our Products
  • Your Cart

Term of Use

  • Privacy Policy
  • Imprint

Find Us At

Location

Lutherstraße 150, 07743 Jena, Germany

FacebookLinkedInYouTube

© 2026 ProtumLink. All rights reserved.

ProtumLink

Find Us At

Location

Lutherstraße 150, 07743 Jena, Germany

FacebookLinkedInYouTube

© 2026 ProtumLink. All rights reserved.