ProtumLink Core 15cm

Column length15cm
Column diameter75μm, 150μm
Stationary phase1.9μm C18

Product Description

Global Proteomics Standard

Core Benefit: Consistency and Coverage for Production Runs

The 15 cm column represents a well-established standard for global proteomics, delivering the separation space required for high coverage while maintaining excellent operational stability.

Chromatographic Excellence (FWHM Resolution)

Chromatographic excellence chart showing FWHM resolution of the 75µm column

At 500 nL/min, the column maintains ~3.5–4.6 s FWHM over 15–45 min gradients, ensuring reliable peak capacity throughout typical global proteomics analyses. This consistency supports high identification rates and robust quantification across extended study designs.

Backpressure Flexibility & Workflow Versatility

With a working flow range of 100–1000 nL/min, the format offers stable retention and dependable long-term performance. It is an excellent choice for core facilities, DIA workflows, and production-style proteomics, where reproducibility from batch to batch is essential.

Pressure profiles

Pressure profiles chart showing backpressure vs flow rate of the 75µm column

High-Capacity Global Proteomics

Core Benefit: Standardized High-Load Coverage

The 15 cm column is designed for users who need consistent performance during extended runs and projects requiring high sample loads. It is a dependable length for routine, high-coverage global proteomics.

Chromatographic Excellence (FWHM Resolution)

Chromatographic excellence chart showing FWHM resolution of the 150µm column

At 200 ng load on a 30-minute gradient, the column produces an FWHM of ~4.6 s, offering solid resolving power and stable performance across multi-day studies.

Backpressure Flexibility & Loading Capacity

Optimized to run at 0.5 µL/min, and supporting flows up to 2 µL/min, the column maintains low and stable backpressure, contributing to long-term robustness. This makes it well-suited for large studies, QC-stable environments, and high-load approaches requiring reproducible retention and minimal maintenance.

Pressure profiles

Pressure profiles chart showing backpressure vs flow rate of the 150µm column

Compatibilities

Core columns are bare fused-silica emitter-integrated analytical columns designed to be connected via a liquid junction. With an outer diameter of 363 μm, they are compatible with liquid junctions engineered for standard 360 μm fused-silica tubing. Depending on the instrument setup, metal junctions can provide grounding or high-voltage transfer, while PEEK junctions may be used when an external grounding or voltage supply point is available. Core columns can also be mounted directly in nanospray sources that are designed to accept bare emitter tips. This includes Thermo Scientific Nanospray Flex and Bruker CaptiveSpray sources (with appropriate emitter positioning accessories such as the CaptiveSpray (CSI) emitter adjustment kit), enabling use of the column itself as the electrospray emitter and minimizing post-column volume. Specific adapter configurations may be required depending on the vendor ion source when using bare emitter columns. Users should consult instrument documentation where compatibility with blank-emitter columns is explicitly described.

Compatible Connection Systems

• Thermo Scientific 6041.5290 nanoViper Fingertight Fitting System, 20 μm

Recommended Liquid Junction Options

• IDEX UH-750 VHP MicroTee® • IDEX UH-634 VHP MicroTight®

C18 Bead Specification

Specification Table

PropertySpecification
Silica BrandReproSil-Pur 120 C18-AQ (Dr. Maisch GmbH)
Chromatographic ModeReversed-phase
Particle Size1.9 µm
Pore Size120 Å
Surface Area300 m²/g
Bonding / PhaseC18 (ODS), fully end-capped, aqueous-compatible
Carbon Load15%
pH Stability Range2 – 8
Max Operating Pressure≤ 1200 bar
Max Operating Temperature60 °C*

*Ultra-fast gradients may be operated up to 70 °C.

Why We Use a Trusted C18 Phase

We rely on a well-established C18 material from Dr. Maisch because it has been widely used in LC–MS–based proteomics for nearly two decades and is known for its stable bonding chemistry, consistent material quality, and reproducible performance. This makes it a dependable foundation for achieving high-quality peptide separations across diverse workflows. The 1.9 µm C18 particles provide a balanced combination of peak capacity, mechanical robustness, and retention stability, supporting sharp and predictable peak shapes under the aqueous mobile-phase conditions typical for proteomics.

Application Notes

Ultra robust performance stability of 25 cm × 75 µm Emitter-Integrated Nanoflow Column with 1.9 µm C18 Material over 800 Samples

PDF - 1.5 MB

Download

High-Sensitivity and Reproducible DIA Performance of a 15 cm × 75 µm Emitter-Integrated Nanoflow Column on the Orbitrap Astral System

PDF - 1.1 MB

Download

Packages

Single300.00€
5-pack1,200.00€
-20% per column
10-pack1,800.00€
-40% per column

Column ID (Diameter)

Sub-total-€
ProtumLink

Our Products

  • ProtumLink Core
  • ProtumLink Union
  • ProtumLink Connect
  • ProtumLink Extend
  • Featured Techniques

About Us

  • About Us
  • Support

Our Stores

  • Our Products
  • Your Cart

Term of Use

  • Privacy Policy
  • Imprint

Find Us At

Location

Lutherstraße 150, 07743 Jena, Germany

FacebookLinkedInYouTube

© 2026 ProtumLink. All rights reserved.

ProtumLink

Find Us At

Location

Lutherstraße 150, 07743 Jena, Germany

FacebookLinkedInYouTube

© 2026 ProtumLink. All rights reserved.